For one of them, comfortably. This size suits a fridge circuit, a diesel heater, a smaller inverter or the feed into a distribution panel. Running two hungry appliances through the same breaker means adding their draw together and sizing the cable — minimum 6mm here — to match.
You need crimped lugs with a 6mm eye to suit the studs, not bare wire twisted under a nut. Strip, crimp with a proper tool, then nip the nuts up — 5.6 N•m is the maximum, and leaning on it cracks the housing instead of making a better connection.
Yes — it is a manual push-to-trip, so you can open the circuit on purpose to work on it safely. Resetting is a separate deliberate action, which is the point. It is not a daily on/off switch though; use a proper switch for that and leave the breaker for protection.